Viglen LX275 Guide de l'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
Viglen LX275 Chassis User Guide
14
Hard Disk Drive Motor Control (J2)
Table 11: Hard Disk Drive Motor Control Options
Operation Mode P1 – P2 P3 – P4 P5 – P6
Normal
Open Open Short
*Delay Start
Short Open Open
Remote Start
Open Short Open
* Default Settings
Normal: Motor spins up at DC power on.
Delay Start: Motor spins up at DC power on after a delay in seconds 12 times the value
of the numeric SEL_ID for the SCSI devices.
Remote Start: Motor spins up only when Start Unit commands is received.
Alarm Temperature (TEMP_SET)
Table 12: Alarm Temperature Options
Temperature P1 – P2 P3 – P4 P5 – P6
45°C
Short Open Open
*55°C
Open Short Open
65°C
Open Open Short
* Default Settings
Fan Monitor Function (FAN_DIS)
Table 13: Fan Monitor Function
Monitor Mode FAN1 P1 – P2 FAN2 P3 – P4
*Disabled
Short Short
Enabled
Open Open
* Default Settings