Intel® Server Board SE7520BD2 User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number:
Contents x No Characters Appear on Screen ...49 Characters Are Distorted
Contents xiFigures Figure 1. Intel® Server Board SE7520BD2 ...13 Figure
Contents xii
Intel® Server Board SE7520BD2 User Guide 13 1 Server Board Features This chapter briefly describes the main features of the Intel® Server Board SE7
Server Board Features 14 Table 1. Server Board Varieties Product Code Memory PCI SCSI SATA USB Connections Product code SE7520BD2 Six DIMM sock
Server Board Features 15Table 1. Server Board Varieties (continued) Product Code Memory PCI SCSI SATA USB Connections Product code SE7520BD2SCS
Server Board Features 16 Table 1. Server Board Varieties (continued) Product Code Memory PCI SCSI SATA USB Connections Product code SE7520BD2V
Server Board Features 17Table 2 summarizes the major features of the server board. See Table 1 for additional information. Table 2. Server Board Feat
Server Board Features 18 Connector and Header Locations Product Codes SE7520BD2, SE7520BD2SCSI, SE7520BD2V TP00718A C EB DGH MKLF IQRPONSTUVWCCEEDD B
Server Board Features 19 A Chassis Intrusion P CPU Power Connector GG SATA A1 B, Left PCI-X* 100 Slot Q DIMM Sockets HH HSBP B B, Right P
ii Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherw
Server Board Features 20 Product Codes SE7520BD2SCSID2, SE7520BD2VD2, SE7520BD2SATAD2 TP01688A C EB DGH MKLF IQRPONSTUVWCCEEDD BBAAYZ XPPRRQQOOSSTTI
Server Board Features 21 A Chassis Intrusion P CPU Power Connector GG SATA A1 B, Left PCI-X* 100 Slot Q DIMM Sockets HH HSBP B B, Right P
Server Board Features 22 Configuration Jumpers TP007233FRBHALTJ4H2RECOVERYBOOTJ4H3J4H13CMOSCLRJ2H13BIOSSELJ1B1NormalBank 0PASSWORDCLEAR Figure 4. Con
Server Board Features 23Back Panel Connectors TP00719HFADG IB C E A USB3 (see note)* D Mouse G Video B USB2 E Keyboard H NIC1 (Management p
Server Board Features 24 Hardware Requirements To avoid integration difficulties and possible board damage, your system must meet the requirements ou
Server Board Features 25Memory For a list of supported memory DIMMs, see: http://support.intel.com/support/motherboards/server/se7520bd2/sb/CS-013543
Server Board Features 26 Intel® Server Boards SE7520BD2SCSID2, SE7520BD2SATAD2, and SE7520BD2VD2 Product codes SE7520BD2SCSID2, SE7520BD2SATAD2, and
Server Board Features 27For memory on-line sparing, one DIMM per channel is used as the memory spare. If a DIMM begins to fail, the content of the fa
Intel® Server Board SE7520BD2 User Guide 28 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay clo
Hardware Installations and Upgrades 29 Installing DIMMs To install DIMMs, follow these steps: 1. Observe the safety and ESD precautions at the begin
Intel® Server Board SE7520BD2 User Guide iii Preface About this Manual Thank you for purchasing and using the Intel® Server Board SE7520BD2. Six ver
Hardware Installations and Upgrades 30 6. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position. 7. Holdi
Hardware Installations and Upgrades 31 Installing the Processor To install a processor, follow these instructions: 1. Observe the safety and ESD pr
Hardware Installations and Upgrades 32 7. Lower the socket lever completely. TP00865 Figure 9. Closing Socket Lever Installing the Heat Sink(s)
Hardware Installations and Upgrades 33Note:Heat sink stylesmay differ.Server Board CutawayHeat Sink Retainer [CEK Spring]TP00721 Figure 10. Installin
Hardware Installations and Upgrades 34 Removing a Processor 1. Observe the safety and ESD precautions at the beginning of this book. 2. Turn off al
Hardware Installations and Upgrades 35Replacing the Backup Battery The lithium battery on the server board powers the RTC for up to 10 years in the a
Hardware Installations and Upgrades 36 TP00724 Figure 11. Replacing the Backup Battery 7 Dispose of the old battery according to local ordinance. 8
Intel® Server Board SE7520BD2 User Guide 37 3 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options,
Server Utilities 38 Table 6 describes the keyboard commands you can use in the BIOS Setup menus. Table 6. Keyboard Commands Press Description <F1&
Server Utilities 39 Upgrading the BIOS ✏ NOTE These instructions describe the process of updating the BIOS only. It is recommented that you check th
Preface iv Product Accessories These server boards are compatible with the following Intel® Server Chassis: Intel® Server Chassis SC5300 Intel
Server Utilities 40 critical information regarding jumper settings, specific fixes, or other information to complete the upgrade. Preparing Media and
Server Utilities 41 ✏ NOTE The CMOS should always be cleared after a BIOS update. You may encounter a CMOS Checksum error or other problem after rebo
Server Utilities 42 Recovering the BIOS In the rare event that the BIOS becomes damaged, a recovery process needs to be followed to return the syste
Server Utilities 43 Manually Recovering the BIOS A BIOS recovery can be manually initiated. This option would be used only when the BIOS is corrupt,
Server Utilities 44 Clearing the Password If the user or administrator password(s) is lost or forgotten, install a jumper on jumper block J4H3 to re
Server Utilities 45 Clearing the CMOS If you are not able to access the BIOS setup screens, the Clear CMOS jumper will need to be used to reset the c
Intel® Server Board SE7520BD2 User Guide 46 4 Troubleshooting This chapter helps you identify and solve problems that might occur while you are usi
Troubleshooting 47 Are all peripheral devices installed correctly? If the system has a hard disk drive, is it properly formatted or configured?
Troubleshooting 48 Verifying Proper Operation of Key System Lights As POST determines the system configuration, it tests for the presence of each mas
Troubleshooting 49 Remove all add-in cards and see if the system boots. If successful, add the cards back in one at a time with a reboot between ea
Preface vProcessors that have been tested with this product Supported Processor List DIMMs that have been tested with this product Tested Memory List
Troubleshooting 50 Characters Are Distorted or Incorrect Check the following: Are the brightness and contrast controls properly adjusted on the vi
Troubleshooting 51CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light Check the following: Are the CD-ROM/DVD-ROM drive’s power and signal
Troubleshooting 52 System Boots when Installing PCI Card System Server Management features require full-time “standby” power. This means some parts o
Troubleshooting 53you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surg
Troubleshooting 54 BIOS POST Beep Codes Boot Block Error Beep Codes Table 7. Boot Block Error Beep Codes Number of Beeps Description 1 Insert disket
Troubleshooting 55 BIOS Beep Codes Table 9. BIOS Beep Codes Number of Beeps Troubleshooting Action 1, 2 or 3 Reseat the memory, or replace with kn
Intel® Server Board SE7520BD2 User Guide 56 Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The Intel®
Regulatory and Compliance Information 57Certifications/Registrations/Declarations UL Certification (US/Canada) CE Declaration of Conformity (
Regulatory and Compliance Information 58 Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operatio
Regulatory and Compliance Information 59 Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioélectriques applicables a
Preface vi System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cor
Intel® Server Board SE7520BD2 User Guide 60 Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SE7520BD2 Telephone All
Getting Help 61In Latin America Brazil 001-916 377 0180 Mexico Contact AT&T USA at 001 800 462 628 4240. Once connected, dial 800 843 4481
Intel® Server Board SE7520BD2 User Guide 62 Intel® Server Issue Report Form Date Submitted: Company Name: Contact Name: Email Address:
Intel® Server Issue Report Form 63Operating System Information Operating System ____________________________________________________________ Versio
Intel® Server Issue Report Form 64 Complete Issue Description In the space below, provide a complete description of the steps used to reproduce the i
Preface vii要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。参见 Resource CD (资源光盘) 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Int
Preface viii
Intel® Server Board SE7520BD2 User Guide ix Contents 1 Server Board Features..................
Commentaires sur ces manuels