Graceful Reboot: same as the reboot function in Windows.
Graceful Power Cycle: this function is a combination of the Graceful Shutdown and Power Up
functions.
The Power Cycle function will shut down the managed system for a few seconds and then power up the
system. Graceful power control will send an event to the System Event Log (next section). If no more
memory space is left for the incoming event, graceful power control will not function.
Chassis Power Control (Administrator and Operator only)
This function is used to forcibly control the power state of the managed system’s chassis. When the
BMC receives a chassis power control command, it will have direct control over the power button or
reset button of a system.
Reset: this is the same as pressing the Reset button on a managed system’s chassis to reset the managed
system.
Power Down: this is the same as pressing the Power button on a managed system’s chassis to remove
power from the managed system.
Power Up: this is the same as pressing the Power button on a managed system’s chassis to turn on the
power of the managed system.
Power Cycle: this function is a combination of the Power Down and Power Up functions.
The Power Cycle function will shutdown the managed system for a few seconds and then power up the
system.
BMC Cold Reset (Administrator only)
Clicking the Cold Reset button allows you to reset the BMC. After confirming to reset the BMC, the
session will break immediately. The user has to close this session manually. This function is rarely used,
only in events such as when a malfunction is suspected.